Shopping Cart
shopping cart
Site map
sitemap
Contact us
contact us
 
AFM Probes:
back » AFM Probes
Registered customers can order AFM probes, tips and cantilevers online. Other products are not available for online ordering.
search afm probes
AFM Probes for Biological Applications
  • FILTER:
  •  new only
  •  • reset
64 matches found
show per page:
  • 10
  • All
  • Loading results. Please wait...
    Order Code Description Specs:
    movebiotool_PNP-TR_10biotool_PNP-TR_10
    Soft Contact AFM Probe for Biological Applications
    • Coating:
      Reflex Gold
    • Tip Shape:
      Cone Shaped, EBD, High-Aspect-Ratio, Supersharp
    • Cantilever:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

    movePPP-NCHAuPPP-NCHAu
    Gold Coated Tapping Mode AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    movePPP-NCLAuPPP-NCLAu
    Gold Coated Tapping Mode AFM Probe with Long Cantilever
    • Coating:
      Gold Overall
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 48 N/m
      res. freq.: 190 kHz

    moveB100_FMRB100_FMR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    movePPP-NCSTAuPPP-NCSTAu
    Gold Coated Soft Tapping Mode AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Standard
    • Cantilever:
      length: 150 µm
      force const.: 7.4 N/m
      res. freq.: 160 kHz

    movePPP-FMAuPPP-FMAu
    Gold Coated Force Modulation AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    movePPP-CONTAuPPP-CONTAu
    Gold Coated Contact Mode AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    movePPP-CONTSCAuPPP-CONTSCAu
    Gold Coated Contact Mode AFM Probe with Short Cantilever
    • Coating:
      Gold Overall
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 0.2 N/m
      res. freq.: 23 kHz

    moveATEC-NCAuATEC-NCAu
    Gold Coated Tapping Mode AFM Probe with a REAL Visible Tip
    • Coating:
      Gold Overall
    • Tip Shape:
      Visible
    • Cantilever:
      length: 160 µm
      force const.: 45 N/m
      res. freq.: 335 kHz

    moveATEC-FMAuATEC-FMAu
    Gold Coated Force Modulation AFM Probe with a REAL Visible Tip
    • Coating:
      Gold Overall
    • Tip Shape:
      Visible
    • Cantilever:
      length: 240 µm
      force const.: 2.8 N/m
      res. freq.: 85 kHz

    moveATEC-CONTAuATEC-CONTAu
    Gold Coated Contact Mode AFM Probe with a REAL Visible Tip
    • Coating:
      Gold Overall
    • Tip Shape:
      Visible
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 15 kHz

    moveTap300GBTap300GB
    Gold Coated Tapping Mode AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Rotated
    • Cantilever:
      length: 125 µm
      force const.: 40 N/m
      res. freq.: 300 kHz

    moveMulti75GB-GMulti75GB-G
    Gold Coated Force Modulation AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Rotated
    • Cantilever:
      length: 225 µm
      force const.: 3 N/m
      res. freq.: 75 kHz

    moveContGB-GContGB-G
    Gold Coated Contact Mode AFM Probe
    • Coating:
      Gold Overall
    • Tip Shape:
      Rotated
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    movePNP-DBPNP-DB
    Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Pyramid
    • Cantilever 1:
      length: 100 µm
      force const.: 0.48 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.06 N/m
      res. freq.: 17 kHz

    movePNP-TRPNP-TR
    Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Pyramid
    • Cantilever 1:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.08 N/m
      res. freq.: 17 kHz

    moveSiNiSiNi
    Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Pyramid
    • Cantilever 1:
      length: 200 µm
      force const.: 0.06 N/m
      res. freq.: 10 kHz

      Cantilever 2:
      length: 100 µm
      force const.: 0.27 N/m
      res. freq.: 30 kHz

    movePPP-BSIPPP-BSI
    Soft Contact AFM Probe for Biological Applications
    • Coating:
      None
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 0.1 N/m
      res. freq.: 28 kHz

    movePPP-NCSTAuDPPP-NCSTAuD

    • Coating:
      Reflex Gold
    • Tip Shape:
      Standard
    • Cantilever:
      length: 150 µm
      force const.: 7.4 N/m
      res. freq.: 160 kHz

    movePPP-NCLAuDPPP-NCLAuD

    • Coating:
      Reflex Gold
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 48 N/m
      res. freq.: 190 kHz

    movePPP-NCHAuDPPP-NCHAuD

    • Coating:
      Reflex Gold
    • Tip Shape:
      Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    movePPP-FMAuDPPP-FMAuD

    • Coating:
      Reflex Gold
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    movePPP-CONTSCAuDPPP-CONTSCAuD

    • Coating:
      Reflex Gold
    • Tip Shape:
      Standard
    • Cantilever:
      length: 225 µm
      force const.: 0.2 N/m
      res. freq.: 23 kHz

    movePPP-CONTAuDPPP-CONTAuD

    • Coating:
      Reflex Gold
    • Tip Shape:
      Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveTap300GDTap300GD
    Gold Coated Tapping Mode AFM Probe
    • Coating:
      Reflex Gold
    • Tip Shape:
      Rotated
    • Cantilever:
      length: 125 µm
      force const.: 40 N/m
      res. freq.: 300 kHz

    moveMulti75GDMulti75GD
    Gold Coated Force Modulation AFM Probe
    • Coating:
      Reflex Gold
    • Tip Shape:
      Rotated
    • Cantilever:
      length: 225 µm
      force const.: 3 N/m
      res. freq.: 75 kHz

    moveContGDContGD
    Gold Coated Contact Mode AFM Probe
    • Coating:
      Reflex Gold
    • Tip Shape:
      Rotated
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveB1_CONTRB1_CONTR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveB1_FMRB1_FMR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveB1_NCHRB1_NCHR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    moveB2_FMRB2_FMR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveB2_CONTRB2_CONTR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveB2_NCHRB2_NCHR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    moveB50_NCHRB50_NCHR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    moveB50_FMRB50_FMR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveB50_CONTRB50_CONTR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveB100_NCHRB100_NCHR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    moveB100_CONTRB100_CONTR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveB150_NCHRB150_NCHR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    moveB150_FMRB150_FMR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveB150_CONTRB150_CONTR
    Special Nanoindentation AFM probe
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      EBD, Rotated, Sphere, Standard
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveCP-PNP-AuCP-PNP-Au
    Special Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Sphere
    • Cantilever 1:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.08 N/m
      res. freq.: 17 kHz

    moveCP-PNP-BSGCP-PNP-BSG
    Special Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Sphere
    • Cantilever 1:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.08 N/m
      res. freq.: 17 kHz

    moveCP-PNP-PMCP-PNP-PM
    Special Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Sphere
    • Cantilever 1:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.08 N/m
      res. freq.: 17 kHz

    moveCP-PNP-PSCP-PNP-PS
    Special Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Sphere
    • Cantilever 1:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.08 N/m
      res. freq.: 17 kHz

    moveCP-PNP-SiOCP-PNP-SiO
    Special Silicon Nitride AFM Probe
    • Coating:
      Reflex Chromium/Gold
    • Tip Shape:
      Sphere
    • Cantilever 1:
      length: 100 µm
      force const.: 0.32 N/m
      res. freq.: 67 kHz

      Cantilever 2:
      length: 200 µm
      force const.: 0.08 N/m
      res. freq.: 17 kHz

    moveCP-CONT-AuCP-CONT-Au
    Special Contact Mode AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveCP-CONT-BSGCP-CONT-BSG
    Special Contact Mode AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveCP-CONT-PMCP-CONT-PM
    Special AFM Probe for Biological Applications
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveCP-CONT-PSCP-CONT-PS
    Special Contact Mode AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveCP-CONT-SiOCP-CONT-SiO
    Special Contact Mode AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    moveCP-FM-AuCP-FM-Au
    Special Force Modulation AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveCP-FM-BSGCP-FM-BSG
    Special Force Modulation AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveCP-FM-PMCP-FM-PM
    Special Force Modulation AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveCP-FM-PSCP-FM-PS
    Special Force Modulation AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    moveCP-FM-SiOCP-FM-SiO
    Special Force Modulation AFM Probe
    • Coating:
      None
    • Tip Shape:
      Sphere
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    movePL2-NCHPL2-NCH
    Tapping Mode AFM Probe with Plateau Tip
    • Coating:
      None
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    movePL2-NCHRPL2-NCHR
    Tapping Mode AFM Probe with Plateau Tip
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 125 µm
      force const.: 42 N/m
      res. freq.: 330 kHz

    movePL2-NCLPL2-NCL
    Tapping Mode AFM Probe with Long Cantilever and Plateau Tip
    • Coating:
      None
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 225 µm
      force const.: 48 N/m
      res. freq.: 190 kHz

    movePL2-NCLRPL2-NCLR
    Tapping Mode AFM Probe with Long Cantilever and Plateau Tip
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 225 µm
      force const.: 48 N/m
      res. freq.: 190 kHz

    movePL2-FMPL2-FM
    Force Modulation AFM Probe with Plateau Tip
    • Coating:
      None
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    movePL2-FMRPL2-FMR
    Force Modulation AFM Probe with Plateau Tip
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 225 µm
      force const.: 2.8 N/m
      res. freq.: 75 kHz

    movePL2-CONTPL2-CONT
    Contact Mode AFM Probe with Plateau Tip
    • Coating:
      None
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz

    movePL2-CONTRPL2-CONTR
    Contact Mode AFM Probe with Plateau Tip
    • Coating:
      Reflex Aluminum
    • Tip Shape:
      Plateau
    • Cantilever:
      length: 450 µm
      force const.: 0.2 N/m
      res. freq.: 13 kHz